国产剧情AV麻豆香蕉精品,国产女人A级毛片18视频,人妻丰满熟人熟妇av无码,久久99国产精品9床震网站

          Language:CHINESESENGLISH

          Homepage > Product > EPS sandwich panels
          Contact Us
          • Address:Pingtang Industrial District, Shipeng Village, Shishan Town, Nanhai District, Foshan City,
          • Phone:0757-81002668/0757-63323396
          • Fax:0757-81196682
          • Contact:梁先生/Mr Leung
          • Phone:18900873383/18900873268
          • E-mail:sbs@sbsprefabhouse.com
          • Skype: sbs-Candy
          • URL:http://www.creadir.com

          EPS sandwich panels

          EPS sandwich panels




          EPS sandwich panel takes the color steel plates as surface layer, the flame-resistant polystyrene foam board as core material, the polyurethane as plasteringagent. The panel is formed by continuous heat and compression, synchronous scale and cut. Under the combination of the polystyrene foam board and plasteringagent, EPS panel can bear the heavy load, therefore its compressive strength is about 100kPa. 

          EPS SANDWICH PANEL SPECIFICATION 

          EPS sandwich panel: 
          Steel thickness: 0.3mm~0.7mm; 
          Sandwich thickness: 50mm~250mm;
          Availability width: 950mm, 1150mm;
          Availability length: By customized.

          EPS SANDWICH PANEL PHYSICAL AND MECHANICAL PROERTIES 

          Item

          Unit

          Index of Properties

          Apparent density  ≤

          kg/m2

          15.0

          20.0

          30.0

          Compression strength (Compressive stress under 10% deformation)  ≥          

          kPa

          60

          100

          150

          Thermal conductivity coefficient ≤

          w/(m.k)

          0.041

          0.041

          0.041

          Water vapor permeability coefficient  ≤

          ng/Pa.m.s

          9.5

          4.5

          4.5

          Water absorbing capacity  ≤

          %

          6

          4

          2

          Oxygen Index  ≥

          %

          30

          30

          30

          Note: Class Ⅰdoes not bear load. Class Ⅱ bears load. Class Ⅲ bears heavy load.
           

          Density (kg/m3)

          Heat conductivity coefficientW/(m.k)
          [Average temperature (70±5)℃]

          Organic content (%)

          Non-flammable

          Maximum temperatur

           

          Density

          Limit deviation

           

          Excellence

          First Grade

          Qualified

           

          80

          ±10

          ±15

          ±20

          ≤0.044

          ≤4.0

          A Grade

          400

           

          100       120

          <0.046

          600

           
           

          150      160

          ≤0.048

           
           

          Item

          Units

          Performance index

          A

          B

          A

          B

          Density  ≥

          kg/m2

          30

          30

          30

          30

          Compression strength (Compressive stress under 10% deformation)           ≥    

          kPa

          100

          100

          100

          150

          Heat conductivity  coefficient   ≤

          w/(m.k)

          0.022

          0.027

          0.022

          0.027

          Water vapor permeability coefficient (23+2)℃/0% to 85%RH  ≤

          ng/Pa.m.s

          6.5

          6.5

          Water absorbing capacity  ≤

             

          %

          4

          3

          Flammability

          gradeⅠ

          Vertical Combustion

          Average burning times (S)

          30

          30

          Average burning intensity (mm)

          250

          250

          grade Ⅱ

          Level Combustion

          Average burning times (S)

          90

          90

          Average burning intensity (mm)

          50

          50


          Characteristics: 
          1)The technology is advanced: Adopt the automatic and continuous equipment, all the main processes are controlled by computer, the quality can reach the industry standard in China. The fireproofing Grade: B3. 

          2) The weight is light: The weight of per square meter sandwich panel is 10~12 kg. The performance in heat reserve and heat insulate is excellent: thermal conductivity λ=0.032 KW/m.h.℃. 

          3) Good rigidity: Because the core materials are shaped, then heat and press them, stick to the upper and the lower surface steel sheet. When the panels are shaped, it has good integrative performance; and also there are wave shapes on the surface of the roof panel, they are stronger than the other same kind materials. The sandwich panel is fixed by the connection and the purlin, then the whole integrative rigidity will be enhanced higher, the whole roof and the wall panels will be enhanced to work well. 

          4)The way of fixation should be tight well and reasonable, the roof panels adopt the M6 self-trapping screw to fix to the purlin, the self-trapping screw will be set on the wave position of the roof panel in order to avoid leaking.  And the self-trapping screw adopts the special constitution, for example the screw adds the whorl constitution and the screw cap add the plastic to protect, in order to reduce the possibility of leaking. 

          5) The way of fixation shall be reasonable; the panel will buckle each other, and then avoid the leaking from the roof panel and save the fittings. 

          6) Protect from scratching: We could use the polythene film on the sandwich panel when they are processed, in order to prevent the surface of the steel from scratching when install and transport.

          Hits:8818 Time:[2018-5-7]

          Copyright:佛山市勝邦鋼結構有限公司 Foshan Shengbang Steel Structure Co., Ltd. Record Number:粵ICP備13078463號