国产剧情AV麻豆香蕉精品,国产女人A级毛片18视频,人妻丰满熟人熟妇av无码,久久99国产精品9床震网站

          Language:CHINESESENGLISH

          Homepage > Product > Floor boards
          Contact Us
          • Address:Pingtang Industrial District, Shipeng Village, Shishan Town, Nanhai District, Foshan City,
          • Phone:0757-81002668/0757-63323396
          • Fax:0757-81196682
          • Contact:梁先生/Mr Leung
          • Phone:18900873383/18900873268
          • E-mail:sbs@sbsprefabhouse.com
          • Skype: sbs-Candy
          • URL:http://www.creadir.com

          Floor boards

          Floor boards

          Floor decking steel sheet
          Floor deck means pressed steel plate not only as a permanent template of concrete floor, but also as load-bearing bar at the bottom of the floor to participate in the stress calculation, to work together with concrete to form a composite floor slab. 

          Performance of composite floor slab: Saving a lot of temporary template; Leaving out all or part of the template support; Cut concrete dosage; Lighten permanent load of the structure; Saving a lot of labor force in transport, storage and installation, which has more important significance in both high-rise buildings and seismic regions; Reducing the workload; Easy laying pipelines of communication, electric power and heating; Also easy laying of heat preservation, sound insulation, heat insulation and vibration isolation material; Improving the floor performance; full playing good steel's tensile strength and ductility and concrete's compressive strength and large stiffness. 
           

           

          Name

          Modle

          Picture

          Thickness(mm)

          Moment of inertia cm3/m

          Section of modulus cm3/m

          Open-type  Floor Deck Sheet

          YX70-200-600 

          0.8

          89.35

          23.7

          0.9

          103.5

          25.7

          1.0

          118.6

          31.6

          1.2

          149.8

          40.01

          YX75-200-600 

          Thickness(mm)

          Moment of inertia cm3/m

          Section of modulus cm3/m

          0.6

          60.38

          16.42

          0.8

          76.57

          20.31

          1.0

          100.64

          27.37

          1.2

          128.19

          35.96

          YX75-293-880

          Thickness(mm)

          Moment of inertia cm3/m

          Section of modulus cm3/m

          0.7

          102.3

          23.481

          0.9

          122.8

          29.52

          1.2

          164.4

          40.464

          1.5

          205.5

          50.313

          YX76-344-688

          Thickness(mm)

          Moment of inertia cm3/m

          Section of modulus cm3/m

          0.8

          91.62

          23.46

          1.0

          119.38

          30.61

          1.2

          142.01

          38.98

          1.4

          167.34

          43.90

          1.5

          178.70

          46.80

          YX51-253-760

          Thickness(mm)

          Moment of inertia cm3/m

          Section of modulus cm3/m

          0.8

          53.80

          19.30

          1.0

          67.30

          24.20

          1.2

          80.80

          29.20

          YX51-240-720

          Thickness(mm)

          Moment of inertia cm3/m

          Section of modulus cm3/m

          0.8

          47.52

          17.9

          0.9

          53.8

          20.1

          1.0

          58.1

          22.9

          1.2

          68.7

          28.4

          YX51-304-914

          Thickness(mm)

          Moment of inertia cm3/m

          Section of modulus cm3/m

          0.8

          106.6

          24.46

          1.0

          127.9

          30.76

          1.2

          171.3

          42.15

          1.5

          214.1

          52.41

          Close Type Floor Decking Sheet

          YX65-185-555

          Thickness(mm)

          Moment of inertia cm3/m

          Section of modulus cm3/m

          0.8

          53.95

          25.614

          1

          67.44

          32.018

          1.2

          80.928

          36.02

          Dovetail Type Steel Floor Sheet

          YX51-190-760

          Thickness(mm)

          Moment of inertia cm3/m

          Section of modulus cm3/m

          0.8

          54.803

          14.42

          1.0

          68.504

          18.02

          1.2

          82.204

          21.63

          1.5

          102.756

          27.04

          YX51-200-600 

           

          Thickness(mm)

          Moment of inertia cm3/m

          Section of modulus cm3/m

          0.8

          54.803

          14.42

          1.0

          68.504

          18.02

          1.2

          82.204

          21.63

          1.5

          102.756

          27.04


          Note: Matters needs attention in floor deck installation 
          Column grid spacing generally is 5~9.0m*8~15m and steel structure beam spacing is 3m. Fabrication length of floor deck is 4.97~8.97m. Transport, ation and installation are more difficult, especially for floor deck with arc vertical hoisting. It is difficult to coat between the beams and narrow down, which also disrupts the second beam welding normal working procedure. Fabrication length is limited to 3~6m, which can avoid lifting problems of secondary girder in vertical transportation. When using special soft sling in hoisting, one should check whether the soft slings are torn or cut off. When floor deck is placed aside the steel beam, it should avoi, , , d probe. When operating, personnel should wear seat belts and ensure that sides' parts are on the perimeter security line. Before using penetration welding spot in welding connection, one should prepare leftover material arc welding, adjust welding current adjustment. Because of no horizontal template and the vertical support plate at the bottom of the floor deck, material should not be too concentrated when watering the concrete. It adopts the planar vibrator and apportions vibrating in a timely manner.

          Hits:9425 Time:[2020-2-26]

          Copyright:佛山市勝邦鋼結構有限公司 Foshan Shengbang Steel Structure Co., Ltd. Record Number:粵ICP備13078463號